{"id":58115,"date":"2019-10-21T09:00:15","date_gmt":"2019-10-21T08:00:15","guid":{"rendered":"http:\/\/blog.phoenixcontact.com\/marketing-gb\/?p=58115"},"modified":"2019-10-21T09:11:13","modified_gmt":"2019-10-21T08:11:13","slug":"do-you-have-issues-when-switching-dc-solenoids","status":"publish","type":"post","link":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/","title":{"rendered":"Do you have issues when switching DC Solenoids?"},"content":{"rendered":"\n<p><em>James West, technical support engineer for Interface technology and switching devices discusses one of the technical problems he regularly gets asked about.<\/em><\/p>\n\n\n\n<p>As a technical support engineer, I get a lot of support\nenquiries requesting replacement relays. Most of these application problems\ncould be avoided by using the correct type of relay. <\/p>\n\n\n\n<p>Solenoids are a common method of controlling valves in an automated machine. They do not have a particularly high holding current, however they are often used in high frequency switching applications and it\u2019s this factor which will cause any associated mechanical relay to eventually fail.<\/p>\n\n\n\n<!--more-->\n\n\n\n<p>DC Solenoids are an inductive load, meaning there will be an initial inrush on start-up, which when using a mechanical relay causes an ARC between the cathode and the anode during the switch from off to on. It\u2019s this arc which, over time, will damage the relay contacts and eventually lead to relay failure.<\/p>\n\n\n\n<p>Most relays can handle this inrush if the switching frequency is low, however if the frequency is high the mechanical life of the relay will be dramatically reduced. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg\" alt=\"\" class=\"wp-image-58118\" width=\"287\" height=\"175\" srcset=\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg 642w, https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01-300x183.jpg 300w, https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01-624x381.jpg 624w\" sizes=\"auto, (max-width: 287px) 100vw, 287px\" \/><\/figure><\/div>\n\n\n\n<p>Phoenix Contact has a wide range of relays that can be used to switch inductive loads. For a solenoid, an SSR (Solid State Relay) can be the perfect switching device. With no mechanical parts there is nothing to cause an arc and no contacts to damage, therefore the life of the relay will be a lot longer.<\/p>\n\n\n\n<p>Selecting\nthe correct SSR is very important as all solid state switching devices have\nmaximum voltage ratings beyond which damage will occur. An over voltage spike\ncan punch through the insulating materials used internally to protect the\ndevice and create a short circuit, so making sure you select the correct relay\nwith the correct protective circuit is crucial. <\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright\"><img decoding=\"async\" src=\"https:\/\/dam-mdc.phoenixcontact.com\/rendition\/156443151564\/f16c6515c34e0f677f03c8d905541958\/-C100%25x100%25%2C0%25%2C0%25-S220x10000\" alt=\"\" \/><\/figure><\/div>\n\n\n\n<p>Phoenix\nContact can provide mechanical and solid state relays for all applications\nwithin automation, from very low current, high frequency data signals, to high\ninrush inductive loads of a motor. <\/p>\n\n\n\n<p>Take a look at the <a href=\"https:\/\/www.phoenixcontact.com\/online\/portal\/gb?1dmy&amp;urile=wcm%3apath%3a\/gben\/web\/main\/products\/subcategory_pages\/Industrial_relays_moduls_with_Push-in_connection_P-16-06-02\/766107e1-e148-4550-9366-eb1d4760f0a3?cpn=blog\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"RIFLINE relay (opens in a new tab)\">RIFLINE relay<\/a> offer in this video:<\/p>\n\n\n\n<figure class=\"wp-block-embed-youtube wp-block-embed is-type-video is-provider-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"RIFLINE Complete: Modular ice-cube relay system - Phoenix Contact\" width=\"625\" height=\"352\" src=\"https:\/\/www.youtube.com\/embed\/FELe1Q5BmEM?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p>For more information or a help in selection please call James on&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 01952 681700 or for a demonstration of any of the Interface range please contact Fraser Cowie on 07584 514963 or at <a href=\"mailto:fcowie@phoenixcontact.com\">fcowie@phoenixcontact.com<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>James West, technical support engineer for Interface technology and switching devices discusses one of the technical problems he regularly gets asked about. As a technical support engineer, I get a lot of support enquiries requesting replacement relays. Most of these application problems could be avoided by using the correct type of relay. Solenoids are a [&hellip;]<\/p>\n","protected":false},"author":24,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[496],"tags":[],"class_list":["post-58115","post","type-post","status-publish","format-standard","hentry","category-best-switching"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Do you have issues when switching DC Solenoids? | United Kingdom<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Do you have issues when switching DC Solenoids? | United Kingdom\" \/>\n<meta property=\"og:description\" content=\"James West, technical support engineer for Interface technology and switching devices discusses one of the technical problems he regularly gets asked about. As a technical support engineer, I get a lot of support enquiries requesting replacement relays. Most of these application problems could be avoided by using the correct type of relay. Solenoids are a [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/\" \/>\n<meta property=\"og:site_name\" content=\"United Kingdom\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-21T08:00:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-10-21T08:11:13+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg\" \/>\n<meta name=\"author\" content=\"Rachel Boyd\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Rachel Boyd\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/\",\"url\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/\",\"name\":\"Do you have issues when switching DC Solenoids? | United Kingdom\",\"isPartOf\":{\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg\",\"datePublished\":\"2019-10-21T08:00:15+00:00\",\"dateModified\":\"2019-10-21T08:11:13+00:00\",\"author\":{\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#\/schema\/person\/e3b56b7feef40f36576e2e4a8701d661\"},\"breadcrumb\":{\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#primaryimage\",\"url\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg\",\"contentUrl\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg\",\"width\":642,\"height\":392},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Do you have issues when switching DC Solenoids?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#website\",\"url\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/\",\"name\":\"United Kingdom\",\"description\":\"PHOENIX CONTACT\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#\/schema\/person\/e3b56b7feef40f36576e2e4a8701d661\",\"name\":\"Rachel Boyd\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#\/schema\/person\/image\/\",\"url\":\"http:\/\/blog.phoenixcontact.com\/wp-content\/uploads\/2015\/09\/Rachel-Boyd_avatar_1441090437-96x96.jpg\",\"contentUrl\":\"http:\/\/blog.phoenixcontact.com\/wp-content\/uploads\/2015\/09\/Rachel-Boyd_avatar_1441090437-96x96.jpg\",\"caption\":\"Rachel Boyd\"},\"description\":\"Digital Marketing Specialist\",\"sameAs\":[\"http:\/\/www.phoenixcontact.co.uk\"],\"url\":\"https:\/\/blog.phoenixcontact.com\/marketing-gb\/author\/rachel\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Do you have issues when switching DC Solenoids? | United Kingdom","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/","og_locale":"en_GB","og_type":"article","og_title":"Do you have issues when switching DC Solenoids? | United Kingdom","og_description":"James West, technical support engineer for Interface technology and switching devices discusses one of the technical problems he regularly gets asked about. As a technical support engineer, I get a lot of support enquiries requesting replacement relays. Most of these application problems could be avoided by using the correct type of relay. Solenoids are a [&hellip;]","og_url":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/","og_site_name":"United Kingdom","article_published_time":"2019-10-21T08:00:15+00:00","article_modified_time":"2019-10-21T08:11:13+00:00","og_image":[{"url":"http:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg","type":"","width":"","height":""}],"author":"Rachel Boyd","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Rachel Boyd","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/","url":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/","name":"Do you have issues when switching DC Solenoids? | United Kingdom","isPartOf":{"@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#primaryimage"},"image":{"@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#primaryimage"},"thumbnailUrl":"http:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg","datePublished":"2019-10-21T08:00:15+00:00","dateModified":"2019-10-21T08:11:13+00:00","author":{"@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#\/schema\/person\/e3b56b7feef40f36576e2e4a8701d661"},"breadcrumb":{"@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#primaryimage","url":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg","contentUrl":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-content\/uploads\/sites\/3\/2019\/10\/Clipboard01.jpg","width":642,"height":392},{"@type":"BreadcrumbList","@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/do-you-have-issues-when-switching-dc-solenoids\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/"},{"@type":"ListItem","position":2,"name":"Do you have issues when switching DC Solenoids?"}]},{"@type":"WebSite","@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#website","url":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/","name":"United Kingdom","description":"PHOENIX CONTACT","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#\/schema\/person\/e3b56b7feef40f36576e2e4a8701d661","name":"Rachel Boyd","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/#\/schema\/person\/image\/","url":"http:\/\/blog.phoenixcontact.com\/wp-content\/uploads\/2015\/09\/Rachel-Boyd_avatar_1441090437-96x96.jpg","contentUrl":"http:\/\/blog.phoenixcontact.com\/wp-content\/uploads\/2015\/09\/Rachel-Boyd_avatar_1441090437-96x96.jpg","caption":"Rachel Boyd"},"description":"Digital Marketing Specialist","sameAs":["http:\/\/www.phoenixcontact.co.uk"],"url":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/author\/rachel\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/posts\/58115","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/comments?post=58115"}],"version-history":[{"count":3,"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/posts\/58115\/revisions"}],"predecessor-version":[{"id":58121,"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/posts\/58115\/revisions\/58121"}],"wp:attachment":[{"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/media?parent=58115"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/categories?post=58115"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.phoenixcontact.com\/marketing-gb\/wp-json\/wp\/v2\/tags?post=58115"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}